1.
DING M, HARPE P, LIU Y H, et al. A 46 μW 13 b 6.4 MS/s SAR ADC with background
mismatch and offset calibration. IEEE Journal of Solid-State Circuits, 2017,
52(2): 423-432.
2.
CHEN L, MA J, SUN N. Capacitor mismatch calibration for SAR ADCs based on comparator
metastability detection. Proceedings of the 2014 IEEE International Symposium
on Circuits and Systems (ISCAS’14), 2014, Jun 1-5, Melbourne, Australia.
Piscataway, NJ, USA: IEEE, 2014: 2357-2360.
3.
GUO H. Design of a 14-bit 250 kS/s SAR ADC with digital background calibration.
Master Thesis. Xi'an, China: Xi’an University of Posts and Telecommunications,
2023 (in Chinese).
4.
DI SALVO A. Design of a 12-bit SAR ADC with digital self-calibration for
radiation detectors front-ends. Proceedings of the 15th Conference on Ph. D
Research in Microelectronics and Electronics (PRIME’19), 2019, Jul 15-18,
Lausanne, Switzerland. Piscataway, NJ, USA: IEEE, 2019: 125-128.
5.
DING X, HOFMANN K, ZHANG L, et al. Redundant double conversion based digital
background calibration of SAR ADC with convergence acceleration and assistance.
Proceedings of the 25th International Conference "Mixed Design of
Integrated Circuits and System" (MIXDES’18), 2018, Jun 21-23, Gdynia,
Poland. Piscataway, NJ, USA: IEEE, 2018: 192-197.
6.
PENG X H, FU T J, BAO Q Q, et al. A new capacitor mismatch calibration
technique for SAR ADCs. Proceedings of the 14th IEEE International Conference
on Solid-State and Integrated Circuit Technology (ICSICT’18), 2018, Oct 31-Nov
3, Qingdao, China. Piscataway, NJ, USA: IEEE, 2018: 4p.
7.
LIU W B, HUANG P L, CHIU Y. A 12-bit, 45-MS/s, 3-mW redundant
successive-approximation-register analog-to-digital converter with digital
calibration. IEEE Journal of Solid-State Circuits, 2011, 46(11): 2661-2672.
8.
LIU W, GUO S S, WANG X, et al. A digital foreground calibration algorithm for
SAR-ADC. Journal of Xi'an University of Posts and Telecommunications, 2021,
26(5): 34-41 (in Chinese).
9.
WANG G H, KACANI F, CHIU Y. IRD digital background calibration of SAR ADC with
coarse reference ADC acceleration. IEEE Transactions on Circuits and Systems
II: Express Briefs, 2014, 61(1): 11-15.
10.
CAO C. Research on high-accuracy SAR ADC and calibration techniques. PhD
Thesis. Xi'an, China: Xidian University, 2017 (in Chinese).
11.
LIU W, GUO S S, WANG X, et al. Background LMS calibration algorithm realization
for SAR-ADC. Proceedings of the 6th International Conference on Integrated
Circuits and Microsystems (ICICM’21), 2021, Oct 22-24, Nanjing, China.
Piscataway, NJ, USA: IEEE, 2021: 142-146.
12.
LIU W. Research and implementation of SAR ADC applied to CZT detector imaging
system. PhD Thesis. Xi'an, China: Northwestern Polytechnical University, 2017
(in Chinese).
13.
ZENG M H. Speech enhancement method based on the least mean squares
optimization algorithm. Journal of Jiaozuo University, 2023, 37(3): 53-58 (in
Chinese).
14.
YE Y F, KE Y J. A variable step size LMS algorithm applied to ultrasonic
non-destructive testing. Information & Communications, 2016, (1): 29-30 (in
Chinese).
15.
ZHANG Y, SHEN J M, WANG Q X, et al. A new variable step size LMS algorithm and
application in speech denoising. Electronics Manufacturing, 2023, 31(16): 93-96
(in Chinese).
16.
HWANG J K, LI Y P. Variable step-size LMS algorithm with a gradient-based
weighted average. IEEE Signal Processing Letters, 2009, 16(12): 1043-1046.
17.
ZHANG L L, TANG X Y, LIU W F. Performance analysis of a new variable step size
LMS adaptive filtering algorithm. Life Science Instruments, 2005, 3(5): 39-41
(in Chinese).
18.
CHEN K. Research on adaptive equalization technology for indoor visible light
communication. Master Thesis. Changchun, China: Changchun University of Science
and Technology, 2019 (in Chinese).
19.
ZHANG J R, ZHANG T. An improved variable step size LMS adaptive filtering
algorithm. Journal of Xi'an University of Posts and Telecommunications, 2021,
26(1): 7-12 (in Chinese).
20.
LIU W, GUO S S, SHANG S G. Design of SAR-ADC with digital self-calibration for
CZT detectors front-ends. Journal of Electronic Measurement and
Instrumentation, 2022, 36(9): 167-173 (in Chinese).
|